 TFS100F.doc
Version 1.1
24.05.2000
VI TELEFILTER
1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: Q-value of matching elements: 2. Characteristics 23 C 0 dBm. for input: for output: 30
Filter Specification
TFS 100F - 1/4
57,5 - 23,5 pF. 70,5 - 23 pF.
( typical value.) ( typical value.)
Remark: Reference level for the relative attenuation arel of the TFS 100 F is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 33 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The bandwidth shift of the filter in the operating temperature range is included in the production tolerance scheme. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data Insertion loss (Reference level) Centre frequency Pass band : Amplitude ripple in pass band (p-p): Bandwidth at ambient temperature TA : 1,3 3 20 33 43 48 dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width arel MHz MHz MHz MHz fc ..... ..... ..... ..... 7,4 fc fc fc fc fc 7,5 8,1 8,5 22,9 95 MHz MHz MHz MHz MHz MHz ae
typ. value 22...22,5 dB 100 MHz
tolerance / limit max. 25 dB
fc at ambient temperature (fCTA)
100 0,1MHz fC - 7,4 MHz.....fC + 7,4 MHz
0,85..1,0 dB
max. 1,3 dB
15,970 15,115 15,560 15,680 15,900 16,000
MHz MHz MHz MHz MHz MHz
min.14,88 MHz min.15,08 MHz max.15,73 MHz max.16,13 MHz max.16,93 MHz
Relative attenuation fc fc 7,4 fc 7,9 fc 8,1 fc 8,5 fc 22,9
35 dB 50 dB 54 dB 54...60 dB 3,47 s 140...155 ns 8-(p-p) 1,7-(r.m.s.) 4 / 4 dB 50 dB 65..70 dB
max. 1,3 dB max. 3 dB min. 33 dB min. 43 dB min. 48 dB min. 50 dB
MHz .....
Group delay (mean value in pass band) : Group delay ripple in pass band (p-p) : Deviation from linear phase in pass band: Input/Output return loss with matching network (S11/S22): Triple transit attenuation compared to main signal Crosstalk attenuation compared to main signal Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Operating temperature range Storage temperature range
max. 3,55 s max. 170 ns
-87 ppm/K fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) - 25 C ... + 80 C - 40 C ... + 85 C
Generated: Checked / Approved :
Dunzow W. Dr. Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS100F.doc
Version 1.1
24.05.2000
VI TELEFILTER
Filter Specification
TFS 100F - 2/4
3. Package,
(All dimensions in mm)
35 Max
12,7 Max
TFS tft
100 Fix M22
Pin 3 - Input. Pin 2 - Input RF Return. Pin 15 - Output. Pin 14 - Output RF Return. Pin 1,4,9,12,13,16,21,24 Package Ground. Pin 10, 11, 22, 23, Not connected.
5,5 Max 4,5 Datecode: K L M .... Year + week 1998 1999 2000
12 7,62 24
3
4
9
12
21 2,54
16 15 14 13 11x2,54 = 27,94
4. 50 - Matching network (see Application Note):
12
3
4
9
12
C1 L1
24 21 16 15 14 13
L4
L3
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS100F.doc
Version 1.1
24.05.2000
VI TELEFILTER
Filter Specification
TFS 100F - 3/4
5. Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS100F.doc
Version 1.1
24.05.2000
VI TELEFILTER
Filter Specification
TFS 100F - 4/4
History Version Reason of Changes Name Date
1.0
- edit filter specifications TFS 100F according to customer requirements.
- edit
Dunzow W.
24.02.2000.
1.1
typical values; - add matching network; - add termination impedance - change limit value of group delay ripple in pass band from max.150 ns to max.170 ns.
Dunzow W.
24.05.2000.
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS100F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X